Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 1

Trial Purpose:

To evaluate one product client is interesting in using for cleaning cables in order to replace TCE

Date Run:

04/30/2009

Experiment Procedure:

About 6 inches of the end of each customer supplied cable were taped off and then Designated ends of the cable were wiped with the cleaner chosen, Vertrel SDG using Wypall reinforced cotton paper towel at room temperature, 68 F, for 10 – 15 seconds with no rinse and they were let to air dry. The cleaned ends were then wrapped in parafilm and the cables were sent back to the client for evaluation. 

Substrates: Varying types of cable jackets including; poly u, poly e, neoprene, xl polyolefin, nylon

Trial Results:

The client supplied cable jackets were cleaned with the Vertrel SDG. There is no way for the lab to know if What was done for cleaning is sufficient until the client contacts us.

Success Rating:

A follow up test, usually based on company input.

Conclusion:

The cables were sent back to the client for analysis on if the jackets were clean enough for the next step in the manufacturing process. Waiting to hear from the client.

Save Report as a PDF