Trial Purpose:

To evaluate aqueous alternatives using ultrasonic cleaning

Date Run:

08/07/2008

Experiment Procedure:

Six products from previous trials were selected for testing. Five of the products were diluted to 20% and the sixth product was diluted to 5%. Products were heated to 130 F and immersed in a Branson 40 kHz ultrasonic tank and degassed for at least five minutes.
Eighteen preweighed coupons were coated with the supplied cutting fluid using a handheld swab and weighed a second time to determine the amount of soil added. Three coupons were cleaned with ultrasonic energy for five minutes, rinsed in tap water for 15 seconds at 120 F and dried using compressed air at room temperature for 30 seconds. Final weights were recorded, and efficiencies calculated for each coupon cleaned.

Trial Results:

Five of the six products removed more than 85% of the oil in the five minutes of cleaning. The last product removed 80%. The table lists the amount of soil added, the amount remaining and the efficiency for each coupon cleaned.

Cleaner Initial wt Final wt % Removed
Shopmaster LpH 0.1368 0.0234 82.89
  0.2761 0.0159 94.24
  0.2485 0.0171 93.12
Aquavantage 1400 GD 0.2711 0.0024 99.11
  0.3318 0.0013 99.61
  0.4337 0.0017 99.61
Shopmaster HP 0.3196 0.0404 87.36
  0.3563 0.0439 87.68
  0.3455 0.0447 87.06
Inproclean 3800 0.4706 0.0020 99.58
  0.3914 -0.0041 101.05
  0.3043 -0.0008 100.26
Bio T 300 B 0.2473 0.0597 75.86
  0.3007 0.0518 82.77
  0.3603 0.0604 83.24
SC Aircraft & Metal Cleaner 0.4117 0.0107 97.40
  0.2978 0.0547 81.63
  1.3744 0.0217 98.42

Success Rating:

Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.

Conclusion:

The same products will be evaluated on the second supplied contaminant following the same conditions.