Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 23

Trial Purpose:

To reevaluate products based on vendor requested dilution raises.

Date Run:

07/11/2003

Experiment Procedure:

The supplied cleaning products were diluted with DI water for all purpose cleaning. Nine preweighed ceramic, Nine plastic G-10 and nine painted steel coupons were coated with Hucker's Soil Formulation (Jif Creamy Peanut Butter 9.2%, Salted Butter 9.2%, Arrowhead Mills stone ground wheat flour 9.2%, Egg Yolk 9.2%, Evaporated milk 13.8%, Distilled water 45.8%, Printer's ink with boiled linseed oil 0.9%, Shaws saline solution 2.7%) using a hand held swab and allowed to dry for 24 hours at room temperature. The contaminated coupons were weighed again to determine the amount of soil added.

Three coupons were placed into a Gardner Straight Line Washability unit. A Professional Painter's Rag was attached to the cleaning sled and soaked with 5-7 sprays of cleaning solutions. Each coupon was sprayed 7-10 times with the same cleaning solution. The cleaning unit was run for 20 cycles (~33 seconds). At the end of the cleaning, coupons were wiped once with a dry paper towel. Final weights were recorded. Efficiencies were calculated and recorded.

Product Dilution Ratio
Envirox H2Orange2 128:1
Ecogent All Purpose 64:1
MD Stetson 101 Neutral 512:1

Trial Results:

The three products were all successful in removing the Hucker's soil from all three substrates. The table lists the amount of soil added and remaining for each coupon cleaned.

Soil Removal

Cleaner Initial wt Final wt % Removed
EnviroxCeramic 0.1159 -0.0007 100.60
  0.1405 0.0098 93.02
  0.0849 0.0024 97.17
EnviroxPlastic 0.0903 0.0036 96.01
  0.0896 0.0017 98.10
  0.0825 0.0067 91.88
EnviroxSteel 0.0424 0.0003 99.29
  0.0734 -0.0008 101.09
  0.0735 -0.0011 101.50
EcogentCeramic 0.1010 0.0080 92.08
  0.0640 0.0090 85.94
  0.0786 0.0114 85.50
EcogentPlastic 0.0617 0.0038 93.84
  0.0822 0.0095 88.44
  0.1102 0.0092 91.65
EcongentSteel 0.0366 -0.0007 101.91
  0.0397 -0.0011 102.77
  0.0810 0.0010 98.77
MDStetsonCeramic 0.0673 0.0104 84.55
  0.0903 0.0088 90.25
  0.0773 0.0110 85.77
MDStetsonPlastic 0.0443 0.0035 92.10
  0.0739 0.0036 95.13
  0.0551 0.0052 90.56
MD StetsonSteel 0.0843 0.0004 99.53
  0.0396 0.0010 97.47
  0.0877 0.0021 97.61

Success Rating:

A follow up test, usually based on company input.

Conclusion:

All three products were successful at the vendor requested dilution ratios.

Save Report as a PDF