Trial Number 0

Trial Purpose:

Grace Daraclean 294xx vs 283 in removing wax

Date Run:

06/01/1995

Experiment Procedure:

The coupons were weighed prior to contamination and then dipped in melted wax.  Once the wax hardened the coupons were then weighed again.  Cleaning was done in a beaker at 160 F with air sparging used as agitation.  The copper coupons were washed for 15 minutes but it was noted that a longer cleaning time was necessary, so the time was bumped up to 20 minutes.  The coupons were then rinsed for 5 minutes in a tap water rinse at 160 F.  Drying was performed by running the coupons under air knives for two minutes and then placing the coupons in a convection oven set at 125 F for 90 minutes.  The coupons were then left out overnight to cool down and then weighed in the morning.  Four runs were performed for the Daraclean 283 (one run for each substrate).

Trial Results:

EXPERIMENTAL DATA LOG

                                                    GRAVIMENTRIC ANALYSIS

sample # and substrate  clean mass (g)  mass with contamination (g)  mass after cleaning (g) contaminant removed (g)  Percent Removal
#8 Aluminum 21.0186 21.8746 21.0205 0.8541 99.78%
#9 Aluminum 21.0070 21.8466 21.0193 0.8273 98.54%
#10 Aluminum 20.9878 21.7173 20.9955 0.7218 98.94%
#2954 Copper 35.2962 36.0450 35.3054 0.7396 98.77%
#3093 Copper 35.3100 36.0492 35.3125 0.7367 99.66%
#3932 Copper 35.3942 36.0962 35.4075 0.6887 98.11%
#5330 Brass 34.5341 35.2604 34.5357 0.7247 99.78%
#7399 Brass 34.7371 35.4442 34.7422 0.702 99.28%
#5881 Brass 34.5893 35.2998 34.5928 0.707 99.51%
#15 Steel 163.8808 165.0326 163.8844 1.1482 99.69%
#11 Steel 139.7609 141.0213 139.7640 1.2573 99.75%
#36 Steel 147.5389 148.6627 147.5427 1.12 99.66%

For the first run the Daraclean 283 removed a majority of the wax, however there was a thin film of wax on the copper coupons.  Thus the cleaning time was bumped up to 20 minutes. Removal was pretty good (except for the Aluminum which had a lot of wax on it), but not as good as the Daraclean 294xx.

Success Rating:

Test incomplete or inconclusive.

Conclusion:

A higher temperature would probably be the best bet to improve cleaning but this might not be a good idea due to safety reasons.  A method needs to be devised to remove the wax from the top of the cleaning tank.