Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 0

Trial Purpose:

To test the effectiveness of aqueous and solvent based cleaners in removing water-based rosin from stainless steel coupons.

Date Run:

06/18/2020

Experiment Procedure:

Three pre-contaminated glass coupons for each of the six cleaners; Sta Sol ESS 160, RB Degreaser, SC Aircraft & Metal Cleaner, Smart Solve 605, Valtron SP 2275, and Ozzy Juice SW-3, were weighed for initial weights. The coupons were soiled with Tacolyn 3570 rosin. Coupons were immersed into beakers with the respective cleaners for 15 minutes at room temperature. Observations were taken in five minute intervals. After immersion, coupons were dried with one wipe from a paper towel and air dry for remaining moisture. Effectiveness of cleaning was determined visually and gravimetrically.

Trial Results:

Cleaner Conc. Initial wt Final wt %Cont Removed % AVG Observations
Sta Sol ESS 160 (Dimethyl Glutarate) 100% 0.0862 0.0238 72.39 62.70 No visual change during immersion
0.0769 0.0322 58.13
0.0804 0.0341 57.59
RB Degreaser 20% 0.0802 0.0863 -7.61 -13.23 No visual change during immersion
0.0749 0.0811 -8.28
0.0786 0.0973 -23.79
SC Aircraft and Metal Cleaner 20% 0.0779 0.0887 -13.86 -5.50 No visual change during immersion
0.0756 0.0775 -2.51
0.0824 0.0825 -0.12
Smart Solve 605  100% 0.0798 0.0039 95.11 90.47 Removal showing after 10 minutes
0.0794 0.0064 91.94
0.0883 0.0138 84.37
Valtron SP 2275 2% 0.0787 0.0807 -2.54 -8.09 No visual change during immersion
0.0885 0.0964 -8.93
0.0695 0.0784 -12.81
Ozzy Juice SW 3 100% 0.0860 0.0870 -1.16 -1.93 No visual change during immersion
0.0801 0.0827 -3.25
0.0805 0.0816 -1.37

Success Rating:

Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.

Conclusion:

Smart Solve 605 was the most effective cleaner in removing the rosin Tacolyn 3570 from the glass coupons.

Save Report as a PDF