Trial Purpose:

Evaluate the efficacy of Client's cleaner formulations on the removal of synthetic blood soil from a stainless steel substrate.

Date Run:

02/26/2026

Experiment Procedure:

15 pre-weighed stainless-steel coupons were coated with synthetic blood using a swab and were allowed to air dry (68 F) for 24 hours. The supplied cleaner concentrates were then diluted by a ratio of 1 oz/ gallon of water. Dirty weights were then recorded. The contaminated coupons were immersed in their respective cleaner at room temperature for two minutes. Following immersion, coupons were rinsed three times in a de-ionized water bath for one minute and dried for 24 hours before the final weights were recorded.

Trial Results:

Cleaner Initial wt Cont. wt Clean wt. Initial wt of cont. Final wt of cont. %Cont Removed % AVG  
Supernova 1.0 49.4977 49.5067 49.4979 0.0090 0.0002 97.78 98.01 slight staining
49.2915 49.3029 49.2917 0.0114 0.0002 98.25 slight staining
Multizyme 60.3355 60.3465 60.3356 0.0110 0.0001 99.09 98.64 slight staining
60.2133 60.2244 60.2135 0.0111 0.0002 98.20 slight staining
Caseprep 63.9995 64.0093 63.9994 0.0098 -0.0001 101.02 88.75  
62.6513 62.6547 62.6521 0.0034 0.0008 76.47 slight staining
Pentazyme 60.5269 60.5387 60.53 0.0118 0.0031 73.72 81.12  
60.9091 60.9178 60.9101 0.0087 0.0010 88.51 slight staining
Pentaprep 62.6866 62.697 62.6885 0.0104 0.0019 81.73 90.86  
62.8221 63.832 62.8223 1.0099 0.0002 99.98  

Success Rating:

Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.

Conclusion:

Based on the results of this test, it is clear that these cleaners were quite effective at removing the soil from the substrate. A coupon from each cleaner was dropped due to equipment inaccuracy, but otherwise the experimental determinations  show that the Multizyme and Supernova 1.0 cleaners were the most effective at removing the soil from the stainless steel coupons with an average removal of 98.64 and 98.01 respectively, but ultimately all cleaners were effective (>80% removal) in removing the soil from the substrate. 