Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 3

Trial Purpose:

To evaluate effectiveness of the provided cleaner in regards to removing synthetic blood from stainless steel.

Date Run:

01/04/2019

Experiment Procedure:

Three pre-weighted stainless-steel coupons were soiled with synthetic blood using a swab and allowed to air dry at room temperature for 24 hours before recording the dirty weights. The coupons were immersed in a beaker with the cleaner for two minutes. Coupons were rinsed in a de-ionized water bath for one minute and dried for 24 hours before recording clean weights.

Trial Results:

Cleaner Initial Wt. Final Wt. % Removal Average
BioGone RTU 0.0010 0.0006 40.00 47.78
0.0016 0.0008 50.00
0.0015 0.0007 53.33

Success Rating:

A cleanliness study, addressing only various analytical techniques.

Conclusion:

BioGone RTU was not considered effective in removing synthetic blood from stainless steel.  