Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 8

Trial Purpose:

To evaluate effective products on supplied contaminants using heated immersion cleaning.

Date Run:

09/24/2008

Experiment Procedure:

Six products were selected from the previous trial based on success on removing the three supplied soils using ultrasonic cleaning. Three products were diluted to 5% using DI water in 400 ml beakers. The other three were used at full strength based on vendor recommendations. Beakers were heated to 130 F on a hot plate. Eighteen preweighed steel coupons were coated with the rust preventative VCI 369 using a hand held swab. Coupons were weighed again to determine the amount of soil added. Three coupons were cleaned in each solution for 10 minutes using stir bar agitation. Coupons were rinsed for 15 seconds in tap water at 120 F and dried using compressed air at room temperature for 30 seconds. Final weights were recorded and efficiencies calculated.

Trial Results:

Only two of the products removed over 85% of the VCI 369 in 10 minutes of immersion cleaning. Two other products removed about 70% and the last two removed under 50%. The table lists the amount of soil added, the amount remaining and the efficiency for each coupon cleaned.

Cleaner Initial wt Final wt % Removed
Aquavantage 1400 GD
  0.1827 0.0569 68.86
  0.1608 0.0547 65.98
  0.2647 0.0738 72.12
Grease Feast      
  0.1912 0.0390 79.60
  0.1244 0.0433 65.19
  0.2118 0.0343 83.81
SC Aircraft & Metal Cleaner
  0.1518 0.1016 33.07
  0.1828 0.0820 55.14
  0.2148 0.1145 46.69
SC MaxiSolve      
  0.3574 0.1281 64.16
  0.1716 0.1138 33.68
  0.1801 0.1172 34.93
Smart Solve 605      
  0.1118 0.0191 82.92
  0.1940 0.0162 91.65
  0.2587 0.0154 94.05
Bean-e-doo      
  0.1882 0.0024 98.72
  0.1248 0.0095 92.39
  0.2969 0.0028 99.06

Success Rating:

A follow up test, usually based on company input.

Conclusion:

The two effective products will be evaluated on VCI 368 using heated immersion cleaning.

Save Report as a PDF