Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 0

Trial Purpose:

To evaluate selected aqueous based low VOC products for manual removal of ink from aluminum coupons.

Date Run:

03/24/2008

Experiment Procedure:

Ten products were selected from the lab's on-line database, www.cleanersolutions.org, based on client supplied information. Products need to have low VOC levels and not contain any hazardous air pollutants. Each product was diluted to 20% using DI Water.
Thirty preweighed aluminum coupons were coated with the supplied Dykem red marking ink using the supplied brush. Once the coupons were dry, a second weight was recorded to determine the amount of ink applied. Three coupons were cleaned for about 2 minutes using a Gardner Straight Line Washability unit. Three coupons were placed into a Gardner Straight Line Washability unit. A WypAll X60 reinforced wiper was saturated with the cleaning solutions and then attached to the cleaning sled. The cleaning unit was run for 75 cycles (~2 minutes). At the end of the cleaning cycle, coupons were wiped dry and weighed again so that efficiencies could be calculated.

Trial Results:

Of the 10 products chosen, none were very effective in removing the ink using manual cleaning. The top four products removed under 10% of the ink. Some of the other products resulted in an increase in final weight over the contaminated weight. This effect could be due to the cleaning solution soaking into the ink, in an attempt to begin to break the ink down. However, no visual cleaning signs were evident after the 2 minutes of wiping. The table lists the amount of ink added, the amount remaining and the efficiency for each coupon cleaned.

Cleaner Initial wt Final wt % Removed
Aquavantage 3800 D 0.0061 0.0071 -16.39
  0.0099 0.0109 -10.10
  0.0477 0.0487 -2.10
Shopmaster 0.0405 0.0397 1.98
  0.0188 0.0191 -1.60
  0.0242 0.0244 -0.83
XL 100 0.0131 0.0129 1.53
  0.0065 0.0049 24.62
  0.0207 0.0204 1.45
SC 1000 0.0311 0.0285 8.36
  0.0137 0.0130 5.11
  0.0091 0.0080 12.09
Optisolv OP7171 0.0402 0.0405 -0.75
  0.0135 0.0133 1.48
  0.0172 0.0175 -1.74
Daraclean 236 0.0185 0.0239 -29.19
  0.0384 0.0400 -4.17
  0.0390 0.0421 -7.95
Eliminator 0.0360 0.0344 4.44
  0.0285 0.0279 2.11
  0.0266 0.0233 12.41
Polychem DeOx 007 0.0165 0.0141 14.55
  0.0154 0.0150 2.60
  0.0124 0.0123 0.81
LPS  Precision Clean 0.0122 0.0121 0.82
  0.0182 0.0172 5.49
  0.0173 0.0167 3.47
Micro 90 0.0208 0.0205 1.44
  0.0198 0.0199 -0.51
  0.0424 0.0414 2.36

Success Rating:

Test showed little or no promise.

Conclusion:

The next trial will attempt to screen potential non-aqueous products for ink removal.