Trial Number 1

Trial Purpose:

To evaluate three products using ultrasonic cleaning to remove buffing compound

Date Run:

02/01/2007

Experiment Procedure:

Three products were selected from previous trial based on effectiveness. Each product was diluted to 5% using DI water in 600 ml beakers. Each solution was heated to 130 F in a Branson 3510 ultrasonic tanked filled with water. The solutions were degassed for 5 minutes.

Nine preweighed coupons were coated with Jackonslea Grey Color 305 A (1344-28-1) by heating the buffing compound to facilitate transfer to the stainless-steel coupons. Once cooled, coupons were weighed again to determine the amount of buffing compound applied. Three coupons were cleaned in each solution for 5 minutes using 40 kHz ultrasonic cleaning. Coupons were rinsed for 15 seconds in 120 F tap water and dried using compressed air at room temperature for 30 seconds. Coupons were weighed a third time to determine the amount of soil remaining and efficiencies were calculated for each coupon cleaned.

Trial Results:

One product, Detergent 8, removed over 95% of the buffing compound up from 85% from cleaning with immersion. The two others removed over 70%. The table lists the amount of buffing compound applied, the amount remaining after cleaning and the efficiency for each coupon cleaned.

Cleaner Initial wt Final wt % Removed
Detergent 8 2.1793 0.1148 94.73
  1.0451 0.0208 98.01
  0.9164 0.0218 97.62
MC 580 1.6800 0.4129 75.42
  1.7418 0.2431 86.04
  1.7951 0.5641 68.58
Polyspray Jet 790 XS 1.7702 0.3367 80.98
  1.5263 0.2592 83.02
  1.5315 0.4558 70.24

Success Rating:

A follow up test, usually based on company input.

Conclusion:

The three products, Detergent 8, MC 530 and Polyspray Jet 790 XS, will be used to clean supplied parts rings using ultrasonic cleaning.