Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 6

Trial Purpose:

To evaluate top five products on sixth supplied contaminant using manual cleaning

Date Run:

11/04/2009

Experiment Procedure:

Five products from the previous trials were selected based on performance. All were used at room temperature. Two alkaline aqueous cleaners were diluted to 5% using DI water in 300 ml beakers. Three cleaners were used at full strength. Fifteen preweighed aluminum coupons were coated with Poseo Premium HPL 6 oil using a handheld swab. The contaminated coupons were weighed again to determine the amount of soil added.

Each cleaner tested with three coupons. Three coupons were placed into a Gardner Straight Line Washability unit. A Kimberly Clark Reinforced paper towel was attached to the cleaning sled and soaked with 5-7 sprays of cleaning solutions. Each coupon was sprayed 3 times with the same cleaning solution. First, Coupon was cleaned for 15 cycles two times; after coupon was cleaned for 15 cycles, experimenter changed the paper towel and soaked with 5 spray of same cleaning solution. At the end of the cleaning, coupons were dried at room temperature naturally. Final weights were recorded and efficiencies were calculated and recorded.

Trial Results:

Four of the five worked very well on the light oil, removing more than 85%. The Activeion unit had the lowest efficiency at 75%. The table lists the amount of oil added, the amount remaining and the efficiency for each coupon cleaned.

Cleaner Initial wt Final wt % Removed
Shopmater RC 100%      
  0.0418 0.0048 88.52
  0.0366 0.0050 86.34
  0.0424 0.0039 90.80
SC Aircraft metal cleaner 5%    
  0.0229 0.0020 91.27
  0.0122 0.0017 86.07
  0.0160 0.0035 78.13
Solsafe 245 100%      
  0.1359 0.0160 88.23
  0.0465 0.0088 81.08
  0.0324 0.0022 93.21
Detergent 8 5%      
  0.0683 0.0045 93.41
  0.0202 0.0025 87.62
  0.0257 0.0037 85.60
Activeion      
  0.0247 0.0020 91.90
  0.0271 0.0099 63.47
  0.0201 0.0054 73.13

Success Rating:

A follow up test, usually based on company input.

Conclusion:

Based on past performance on the previous contaminants, all five products will be tested on the next supplied contaminant under the same conditions.

Save Report as a PDF