Trial Number 3

Trial Purpose:

To evaluate top five products on third supplied contaminant using manual cleaning

Date Run:

10/28/2009

Experiment Procedure:

Five products from the previous trials were selected based on performance. All were used at room temperature. Two alkaline aqueous cleaners were diluted to 5% using DI water in 300 ml beakers. Three cleaners were used at full strength. Fifteen preweighed aluminum coupons were coated with Mobile DTE 25 oil using a handheld swab. The contaminated coupons were weighed again to determine the amount of soil added.

Each cleaner tested with three coupons. Three coupons were placed into a Gardner Straight Line Washability unit. A Kimberly Clark Reinforced paper towel was attached to the cleaning sled and soaked with 5-7 sprays of cleaning solutions. Each coupon was sprayed 3 times with the same cleaning solution. First, Coupon was cleaned for 15 cycles two times; after coupon was cleaned for 15 cycles, experimenter changed the paper towel and soaked with 5 spray of same cleaning solution. At the end of the cleaning, coupons were dried at room temperature naturally. Final weights were recorded and efficiencies were calculated and recorded.

Trial Results:

All five products removed more than 90% of the oil from the aluminum coupons using simulated manual cleaning. The table lists the amount of soil added, the amount remaining and the efficiency for each coupon cleaned.

Cleaner Initial wt Final wt % Removed
Buckerye_Shopmater RC 100%  
  0.1004 0.0128 87.25
  0.2172 0.0142 93.46
  0.2324 0.0156 93.29
Gemtek_SC Aircrafe metal cleaner 5%  
  0.2534 0.0128 94.95
  0.2249 0.0114 94.93
  0.2654 0.0067 97.48
Biochem_Solsafe 245 100%  
  0.2059 0.0139 93.25
  0.2127 0.0135 93.65
  0.2246 0.0093 95.86
Alconox_Detergent 8 5%    
  0.1148 0.0091 92.07
  0.2454 0.0083 96.62
  0.2292 0.0103 95.51
Activion       
  0.2715 0.0175 93.55
  0.2483 0.0103 95.85
  0.2557 0.0183 92.84

Success Rating:

A follow up test, usually based on company input.

Conclusion:

The same five products will be tested on the fourth supplied soil under the same conditions.

Save Report as a PDF