Trial Number 3

Trial Purpose:

To evaluate five products on the fourth supplied soil

Date Run:

05/12/2004

Experiment Procedure:

Five cleaners were selected from the previous trial. All were aqueous based and were diluted to 5% using DI water in 600 ml beakers. All six products were heated to 120 F on a hot plate.

Fifteen preweighed titanium coupons were coated with client supplied peanut oil, using a hand held swab and then weighed a second time to determine the amount of soil added. Three coupons were cleaned in each solution for 5 minutes using stir-bar agitation. Coupons were rinsed in tap water for 15 seconds at 120 F, followed by air blow off at room temperature. Once dry, coupons were weighed a final time and efficiencies for each cleaner were calculated.

Trial Results:

All five products removed over 98% of the oil in five minutes. Three of the five removed over 99%. The table lists the amount of oil added, the amount remaining and the efficiency for each coupon.

Cleaner Initial wt Final wt % Removed
SC Aircraft & Metal Cleaner 0.1518 0.0024 98.42
  0.1971 0.0012 99.39
  0.0836 0.0024 97.13
Micro 90 0.1452 0.0003 99.79
  0.0777 -0.0003 100.39
  0.1994 0.0005 99.75
Daraclean 282 GF 0.0870 0.0006 99.31
  0.1537 0.0005 99.67
  0.0984 0.0003 99.70
Inproclean 3800 0.1430 -0.0001 100.07
  0.1101 0.0002 99.82
  0.1125 0.0004 99.64
Beyond 2004 0.1036 0.0004 99.61
  0.1144 0.0019 98.34
  0.2136 0.0038 98.22

Success Rating:

Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.

Conclusion:

The five products will all be tested on the flux. In addition, a few other products will be added for evaluation.

Save Report as a PDF