Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 0

Trial Purpose:

To evaluate selected vapor degreasing solvents on first oil.

Date Run:

04/13/2004

Experiment Procedure:

Six products were selected based on client request for vapor degreasing solvents. Each product was used at full strength in a 250 ml beaker and heated to 96 F on a hot plate. Eighteen preweighed aluminum coupons were coated with the Soltex Polybutene 32 (9003-29-6) using a hand held swab. Coupons were weighed a second time to determine the amount of soil added to each coupon. Three coupons were cleaned in each solution for 5 minutes using stir-bar agitation. After cleaning parts were weighed a final time and efficiencies were calculated.

Trial Results:

Four of the products, 71DE, AK 225, CCA and MCA, removed over 94% of the soil in the five minutes of immersion cleaning. The other two products removed less than 20%. Even after increasing cleaning time to ten minutes, these two products had only marginal success, removing less than 40%. The table below lists the amount of soil added, remaining and efficiencies for each coupon cleaned.

Cleaner Initial wt Final wt % Removed
HFE 7100 0.6255 0.4415 29.42
  0.3452 0.3569 -3.39
  0.5307 0.5216 1.71
HFE 7200 0.2486 0.2254 9.33
  0.4331 0.38 12.26
  0.4522 0.2914 35.56
HFE 71DE 0.4494 0.0091 97.98
  0.3842 0.0171 95.55
  0.4593 0.0062 98.65
AK 225 0.3207 0.0157 95.10
  0.5828 0.0309 94.70
  0.5086 0.0393 92.27
HFE 7100 (10 min) 0.6255 0.4209 32.71
  0.3452 0.3468 -0.46
  0.5307 0.4635 12.66
HFE 7200 (10 min) 0.2486 0.2059 17.18
  0.4331 0.2221 48.72
  0.4522 0.2140 52.68
CCA 0.8681 0.0234 97.30
  0.5975 0.0041 99.31
  1.0897 0.0532 95.12
MCA 0.4396 0.0211 95.20
  1.0074 0.0182 98.19
  0.6466 0.0126 98.05

Success Rating:

Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.

Conclusion:

Longer cleaning time (30 minutes) may help to improve the effectiveness of 7100 and 7200. Increasing the temperature of all the products could also improve the removal of this soil. All six products will be tested on the second supplied soil.

Save Report as a PDF