Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 17

Trial Purpose:

To evaluate the effectiveness of SB-2, SB-11, SB-22, SB-23, and SB-32 in removing LMKT Lapping Compound from copper and brass coupons as a potential replacement for TCE with an unheated ultrasonic cleaning method.

Date Run:

02/26/2024

Experiment Procedure:

Three copper and brass coupons were used for each cleaner being tested, for a total of 15 coupons per cleaner. The initial weights of each coupon were recorded. The bottom third of every coupon was soiled by applying the contaminate with a swab. The dirty weights of each coupon were then recorded. The coupons were then subjected to unheated ultrasonic in the cleaners for 15 minutes. After the coupons were cleaned, they were left to air-dry overnight. The next morning, the clean weights of each coupon were taken.

Trial Results:

Substrate Cleaner Coupon # Initial Content Weight Final Content Weight Percent Content Removed Average Percent Removed

 

 

 

 

 

 

 

Copper

 

 

 

 

 

 

 

SB-2

2 0.0615 0.0981 -59.51

 

-101.13

12 0.0429 0.0935 -117.95
15 0.0351 0.0793 -125.93

 

SB-11

7 0.0293 0.0327 -11.60

 

-20.67

17 0.0301 0.0429 -42.52
21 0.0266 0.0287 -7.89

 

SB-22

11 0.0497 0.0012 97.59

 

102.46

23 0.047 0.0006 98.72
27 0.0217 -0.0024 111.06

 

SB-23

1 0.0369 -0.0006 101.62

 

98.63

14 0.0326 0.0009 97.24
31 0.0303 0.0009 97.03

 

SB-32

3 0.0617 -0.0009 101.46

 

103.42

6 0.0339 -0.0021 106.19
16 0.0424 -0.0011 102.59

 

 

 

 

 

 

 

Brass

 

 

 

 

 

 

 

SB-2

9 0.0181 0.0161 11.05

 

24.35

11 0.0494 0.0251 49.19
25 0.0234 0.0204 12.82

 

SB-11

12 0.0202 0.0325 -60.89

 

-3.04

14 0.0378 0.0277 26.72
23 0.0379 0.0284 25.07

 

SB-22

4 0.0454 -0.0027 105.95

 

109.58

15 0.0281 -0.004 114.23
17 0.028 -0.0024 108.57

 

SB-23

2 0.0245 -0.0027 111.02

 

106.20

8 0.0201 -0.0026 112.94
10 0.0636 0.0034 94.65

 

SB-32

16 0.0502 -0.0054 110.76

 

99.67

18 0.0503 0.0078 84.49
34 0.0585 -0.0022 103.76

Success Rating:

Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.

Conclusion:

SB-2 and SB-11 did not dry properly overnight, making their final contents higher than their initials. SB-22 and SB-23 seemed like effective alternatives, but due to the "overcleaning" causing negative percent removals, further testing could be done to create the ideal range of cleaning time and contaminants added. SB-32 turned light blue after testing, this was caused by the Ethyl Lactate stripping copper ions from the metal and the mixture will not be used in further testing.

Save Report as a PDF