Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 450

Trial Purpose:

To remove maintenance soil from stainless steel using ultrasonic cleaning

Date Run:

06/17/2008

Experiment Procedure:

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Products were selected based on the compatibility of substrate and for removal of the contaminant. Five percent concentrations were used and heated the samples at 104 F. The coupons were cleaned in a product for 20 minutes using ultrasonic cleaning, rinsed with tap water at 105 F and dried at room temperature using compressed air blow off. Coupons were coated with used maintenance soil using a handheld swab and allowed to dry for 20 minutes at room temperature. The contaminated coupons were weighed again to determine the amount of soil added. After cleaning process, the final weights were recorded, efficiencies were calculated and recorded.

Trial Results:

Cleaner Initial wt Final wt % Removed
Inproclean 3800      
  0.1008 0.0188 81.35
  0.1001 0.0128 87.21
  0.0943 0.0187 80.17
Polyspray Jet 790 XS      
  0.0926 0.1061 -14.58
  0.1650 0.0592 64.12
  0.1280 0.0211 83.52
Micro 90      
  0.0781 0.0189 75.80
  0.0975 0.0442 54.67
  0.1504 0.0272 81.91
Shopmaster LpH      
  0.1253 0.0643 48.68
  0.1129 0.0957 15.23
  0.1067 0.0457 57.17
BG Solve 717      
  0.1062 0.0228 78.53
  0.0995 0.0515 48.24
  0.1066 0.1016 4.69
Hurrisafe 9450      
  0.1322 0.0587 55.60
  0.1010 0.0634 37.23
  0.1070 0.0698 34.77
Daraclean 282 GF      
  0.1254 0.0749 40.27
  0.1126 0.0809 28.15
  0.0970 0.0527 45.67

Success Rating:

Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.

Conclusion:

No product removed over 85%. Inproclean 3800 removed about 83%.