Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 332

Trial Purpose:

Laboratory evaluations of alternative cleaning products

Date Run:

05/26/2004

Experiment Procedure:

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

All products were used heated to 96 F on a hot plate in 250 ml beakers. Eighteen preweighed steel coupons were coated with a varnish mix containing Cooper's Creek Chemicals, Cooper Black Tank Paint No 739 (64742-89-8, 8052-42-4, 108-88-3); Sherwin Williams Company, V74B2 Black Asphaltum coating (64742-89-8, 64742-88-7, 8052-42-4) using a handheld swab. The oil was then heated with a Master Appliance Heat gun at 300 F for 10 minutes. After cooling to room temperature, a second weighing was performed to determine the amount of soil that was added. Three coupons were cleaned in each solution for 5 minutes with minimal stir-bar agitation. After drying, coupons were weighed a final time to determine the cleaning efficiency of each product.

Trial Results:

Cleaner Initial wt Final wt % Removed
Vertrel MCA 0.1033 0.0490 52.57
  0.0739 0.0587 20.57
  0.4764 0.1710 64.11
Heavy Duty Degreaser C 0.4009 0.1452 63.78
  0.1833 0.1334 27.22
  0.4228 0.3069 27.41
HFE 7100 0.2702 0.1881 30.38
  0.3106 0.2235 28.04
  0.0964 0.0768 20.33
OS 10 0.1747 0.1165 33.31
  0.6643 0.4647 30.05
  0.2005 0.1801 10.17
OS 20 0.1024 0.0755 26.27
  0.1767 0.1214 31.30
  0.4048 0.2911 28.09
OS 30 0.0619 0.0582 5.98
  0.3670 0.2762 24.74
  0.0697 0.0646 7.32

Success Rating:

Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.

Conclusion:

No product removed over 50% of the contaminant.