Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 120

Trial Purpose:

Laboratory evaluations of alternative cleaning products

Date Run:

12/17/2001

Experiment Procedure:

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Cleaning: 5 min. Immersion at 120  F with stir-bar agitation. Rinsing  : 1/2 min, manual in water at 120 F
Drying    : Drying at room temperature for 16 hrs.
Contaminant : Castrol Inc. -Braycote Perfluoropolyether High Temperature lubricating grease.

Trial Results:

There was increase in weight of some coupons. This is due to the fact that grease was not removed at all from the coupons and it retained the water.

Success Rating:

Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.

Conclusion:

Failure of all the cleaners.