Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 115

Trial Purpose:

Laboratory evaluations of alternative cleaning products

Date Run:

11/27/2001

Experiment Procedure:

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

(i) 5 minute  immersion cleaning with stir bar agitation @ 120 degree F.
(ii) 30 sec manual rinse with water @120 degree F.
(iii) air drying for about 24 hours.
CONTAMINANT INFO: Oil base offset ink, 3-2020 Electrostatic Black

Success Rating:

Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.

Save Report as a PDF