Browse Client Types

Browse past lab clients by general industry sectors

Client #146

Chemical

Chemical Company

Related Images

Project Number 1

Summary:

Testing identified two alternatives, Buckeye Shopmaster with 40 kHz ultrasonics, or tap water using 25 kHz ultrasonic's.

Test Objective:

To clean a static mixing tube

Product Use:

mixing chemicals
Trial Number Date Run Purpose Success Rating
0 11/29/2000 To identify an aqueous cleaner that would improve the cleaning of static mixers. Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
1 11/29/2000 To further evaluate the effectiveness of five previously tested products A follow up test, usually based on company input.
2 11/30/2000 To clean supplied part using most effective cleaner from previous trials. A follow up test, usually based on company input.
3 01/18/2001 To identify additional cleaning products for static mixer cleaning. A follow up test, usually based on company input.
4 01/19/2001 To evaluate the effectiveness on cleaning the supplied parts using ultrasonics with the two effective cleaners from the previous trial. A follow up test, usually based on company input.
5 01/23/2001 To evaluate semi-aqueous alternatives. A follow up test, usually based on company input.