Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 3

Trial Purpose:

Perform a material compatability test

Date Run:

01/04/1996

Experiment Procedure:

The purpose of this trial is perform a material compatibility test for Silversmith.  The compatibility of the WR Grace Daraclean 211, Calgon 2215, and the U.S. Polychem #790 Poly Spray Jet with brass parts.  Each solution was made up at a 20% concentration.  Two brass coupons were submerged in each beaker for 2 hours at temperatures of 130, 140, 150 and 160 F.  After one hour, the coupons were visually analyzed for any etching or discoloration that might have taken place.

Trial Results:

  WR Grace Calgon U.S. Polychem
Temperature Daraclean 211 Geo-Guard 2215 790 Poly Spray Jet
130 pass pass pass
140 pass pass pass
150 pass pass pass
160 pass pass pass

Success Rating:

Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.

Conclusion:

All cleaners were brass compatible when immersed in excessive cleaner chemistries for an excessive amount of time.  The cleaning stage should not pose a problem with the brass, but the rinse stage must be kept at a low temperature to avoid etching and spotting.  Both brass and silver parts from Silversmith will be tested in the Miele spray washing system as soon as the new program card is received from Miele.

Save Report as a PDF