Trial Number 5

Trial Purpose:

6th contaminant cleaning

Date Run:

04/11/2002

Experiment Procedure:

Thirteen preweighed coupons were coated with Solutia Gelva 2895 (50862-46-9; 141-78-6; 142-82-5; 67-63-0; 64-17-5; 108-05-4) with a hand held swab. Coupons were reweighed. Five coupons were clipped to wire racks and immersed into the Flow-Matic machine and cleaned for 1 minutes using ultrasonics at 92 F, removed and rinsed in a tap water spray and re-immersed into the ultrasonics for an additional 1 minute followed by a second 5 second rinse. The coupons were then dried using an air knife for 15 seconds. A second set of five coupons followed the same cleaning cycle except they were hung on a wire stand and immersed into a Crest 40 kHz ultrasonic tank. The final three coupons were cleaned in water using stir-bar agitation, rinsed with the spray and dried with air knives.

Trial Results:

Comparison of the two processes revealed that both system were ineffective at removing the resin from the stainless steel coupons.

Table 1. Cleaning Efficiencies

Process Flow-Matic Traditional
  13.35 10.72
  11.87 14.07
  13.03 10.22
  10.87 14.31
  13.80 15.48
Average 12.59 12.96
Std Dev 1.20 2.34

Water in the immersion cleaning removed the same amount of resin as the ultrasonic systems.
Gelva
13.66
10.61
13.57
12.61 Average
1.737 Std Dev

Success Rating:

A follow up test, usually based on company input.

Conclusion:

Neither system was effective in cleaning the resin.