Client #116

Cleaning Product Manufacturer

Cleaning Equipment Mfr

Related Images

Project Number 1

Summary:

Upon initial analysis of parts cleaned at client facility, inconclusive results were obtained. System will be evaluated in lab.

Test Objective:

To evaluate cleaning capabilities of new ultrasonic cleaning system
Trial Number Date Run Purpose Success Rating
0 11/10/1999 To evaluate cleaning efficiency of new system which uses no chemistries. A cleanliness study, addressing only various analytical techniques.
1 11/23/1999 To evaluate standard ultrasonic cleaning system and water for cleaning oil from steel. A follow up test, usually based on company input.

Project Number 2

Summary:

System was evaluated in the lab. Results showed the ultrasonic cleaning with water was the same for the new equipment and old equipment. The use of a pressure spray rinse was found to be beneficial to the cleaning process.

Test Objective:

In house evaluation of ultrasonic cleaning system
Trial Number Date Run Purpose Success Rating
0 04/03/2002 1st contaminant cleaning Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
1 04/04/2002 2nd contaminant cleaning A follow up test, usually based on company input.
2 04/09/2002 3rd contaminant cleaning A follow up test, usually based on company input.
3 04/09/2002 4th contaminant cleaning A follow up test, usually based on company input.
4 04/09/2002 5th contaminant cleaning A follow up test, usually based on company input.
5 04/11/2002 6th contaminant cleaning A follow up test, usually based on company input.
6 04/11/2002 7th contaminant cleaning A follow up test, usually based on company input.
7 04/12/2002 Follow up evaluation of spray rinse. A follow up test, usually based on company input.