Project Number 1

Summary:

Recommendations were made on chemistries and equipment which have been successfully implemented at the company. A manually operated aqueous immersion station is being used with a chemistry manufactured by the client, KPC 820 N.

Test Objective:

To try to replace two parts cleaners using methanol, MEK and xylene with a water based product.

Product Use:

mixing blades for product mixing; pipe fittings for transfer and miscellaneous tools for mixing and transferring operations.
Trial Number Date Run Purpose Success Rating
0 07/10/1995 To remove microscopic metal fines Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
1 07/11/1995 Positions down for cleaning Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.
2 07/18/1995 Test effectiveness of AW Chesterton KPC 820N Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.