Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 1

Trial Purpose:

Determining HSP Sphere coordinates for Flexcon's 7777 performance coating

Date Run:

11/05/2025

Experiment Procedure:

24 scintillation vials were filled with 24 different solvents from TURI's HSP matrix. The 7777 performance coating was spread onto wax paper and allowed to air dry for 3-4 hours. After it was dry, but not hardened, balls of adhesive were scraped into each of the 24 scintillation vials and allowed to soak. For the first hour, visual observations were taken every 10 minutes, then following the first hour observations were taken every half hour up until 3 hours. The vials were then allowed to sit overnight before final observations were taken. 

Trial Results:

1 - Toluene 1
2 – Dimethyl Carbonate 0
3 - Xylenes 1
4 – Benzyl Alcohol 0
5 – Ethylene glycol 0
6 – Methyl Acetate 0
7 - Undecane 0
8 – Ethyl Lactate 0
9 – Acetone 0
10 – Ethyl Acetate 1
11 – Methanol 0
12 – Ethanol 0
13 – 1,3-dioxolane 1
14 – Diethyl Carbonate 1
15 – 1-propanol 1
16 – Isopropanol 0
17- Propylene Carbonate 0
18 – Thiophene 1
19 – 1-Methoxy-2-Propanol 0
20 – Dimethyl Sulfoxide 0
21 – 1-Butanol 0
22 – Dimethyl glutarate 0
23 – Anisole 1
24 – 2-Butoxyethyl-Acetate 1

Success Rating:

Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.

Conclusion:

Based on the results of this test, Toluene, Xylene, Ethyl Acetate, 1,3-dioxolane, Diethyl Carbonate, 1-propanol, Thiophene, Anisole, and 2-butoxyethyl-acetate were successful in dissolving the target soil. The other 15 solvents did not succeed in dissolving the target soil

Save Report as a PDF