Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 2

Trial Purpose:

Testing the efficacy of MPlus to 7th Generation All Purpose for removing Hucker's Soil from ceramic, plastic, and painted metal.

Date Run:

01/08/2025

Experiment Procedure:

Nine pre-weighed coupons per cleaner (three ceramic, three plastic, and three painted metal) were soiled with 0.5 grams of Hucker's Soil using a handheld swab and air-dried for 24 hours at room temperature (68°F). The contaminated coupons were weighed after 24 hours to determine the contaminated (cont.) weight. Three coupons of the same substrate were placed onto the Straight Line Washing (SLW) Unit with Wypall X60 attached to the cleaning sled. The Wypall X60 reinforced wipe and each coupon on the SLW unit were treated with three sprays each before running the SLW unit for 20 cycles (30 seconds). At the end of the cleaning cycle, the coupons were air-dried overnight before the final weights were recorded.

Trial Results:

Cleaner Substrate Initial wt of cont. Final wt of cont. % Cont. Removed Average % Removal  Overall Cleaner Average % Removal
MPlus Ceramic 0.2768 0.0796 71.24 74.56 80.33
0.3069 0.0724 76.41
0.2583 0.0619 76.04
Plastic 0.2509 0.0261 89.60 94.29
0.2728 0.0178 93.48
0.2589 0.0005 99.81
Painted Metal 0.2662 0.0791 70.29 72.15
0.2620 0.0536 79.54
0.2444 0.0816 66.61
7th Generation All Purpose Ceramic 0.2537 0.0504 80.13 84.02 86.33
0.2717 0.0281 89.66
0.2446 0.0434 82.26
Plastic 0.2728 0.0201 92.63 97.07
0.2677 0.0024 99.10
0.2807 0.0015 99.47
Painted Metal 0.2580 0.0653 74.69 77.90
0.2782 0.0307 88.96
0.2673 0.0801 70.03

Success Rating:

Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.

Conclusion:

MPlus was effective overall at removing Hucker's Soil from various substrates and performed similarly to 7th Generation All Purpose cleaner. 

Save Report as a PDF