Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 11

Trial Purpose:

The purpose of this experiment was to determine the effectiveness of top cleaners and method on removing the vanishing oil.

Date Run:

02/09/2021

Experiment Procedure:

Cleaners were prepared to the following concentrations: Metalnox 6386 100%, Water Works Heavy Duty Degreaser 7:1, SC Aircraft & Metal Cleaner 20%. Cleaners and an ultrasonic bath were heated to 100°F. Three aluminum coupons were obtained and weighed for each of the cleaners being tested. Coupons were then soiled with the V-4B oil and a dirty weight was recorded. Once solutions reached the proper temperature, coupons were submerged into their respective cleaners and ultrasonic cleaning was conducted for 15 minutes. After the 15 minutes, coupons cleaned with SC Aircraft were rinsed in a deionized water bath at 100°F for 30 seconds. All coupons were then partially dried with a heat gun to remove excess solution and finished drying in air for 24 hours. Following the drying step, coupons were weighed again and a clean weight was recorded. Effectiveness of the cleaners was determined.

Trial Results:

Cleaner Initial wt of Cont. Final wt of Cont. %Cont. Removed %AVG
Metalnox 6386 0.0513 0.0003 99.42 99.44%
0.0348 0.0003 99.14
0.0416 0.0001 99.76
Water Works 0.0388 0.0023 94.07 90.88%
0.0371 0.0035 90.57
0.0275 0.0033 88.00
SC Aircraft & Metal 0.0403 0.0005 98.76 97.27%
0.0271 0.0014 94.83
0.0452 0.0008 98.23

All cleaners were effective at removing the vanishing oil from aluminum substrates via the heated ultrasonic method. There was no visible residue or markings of potential damage on any of the cleaned coupons. Next steps would be to test the cleaners and method on copper substrates.

Success Rating:

Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.

Conclusion:

Upon completion of testing it was determined that all cleaners were effective at removing the vanishing oil via heated ultrasonics. Next steps would be to conduct testing on copper substrates with the aviation grease.

Save Report as a PDF