Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 9

Trial Purpose:

To conduct testing on possible drop in solvents for cleaning of the Dow Corning Vacuum grease.

Date Run:

03/28/2016

Experiment Procedure:

Brass coupons were arranged into rows of 3. Once the initial weights were taken, the lower third of the coupons were soiled. The coupons were places into the solvent drop in replacement solutions.  Observations were taken during the process. The coupons were immersed for 5 minutes and removed to air dry on a drying rack for 15 minutes.  Final weights were recorded once the coupons were dried.

Trial Results:

Cleaner Initial wt. Final wt. %Cont Removed
Vertrel Sion 0.4790 0.3457 27.83
  0.4023 0.2601 35.35
  0.4640 0.3345 27.91
Fluosolv FR-110 0.5254 0.5131 2.34
  0.4787 0.4662 2.61
  0.5132 0.5019 2.20
Fluosolv CX-500 0.3918 0.3662 6.53
  0.5192 0.4965 4.37
  0.4693 0.4527 3.54

Success Rating:

Test incomplete or inconclusive.