Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 0

Trial Purpose:

Abraision Testing of Series 1

Date Run:

09/17/2015

Experiment Procedure:

The TURI Lab recently completed an evaluation on the life span of the ozone in a Series 1. Tersano Series 1 is reported to stabilize sanitation time for up to four hours, operating time for up to 3 days, and have a filter cartridge life of 1,600 gallons. It claims to replace all all-purpose cleaners, stainless steel cleaners, glass cleaners, neutral cleaners, and deodorizers.

Initial weights of stainless-steel coupons were recorded and then coated with 0.5 grams of DCC-17 soil. The coupons air dried overnight and dirty weights were recorded the next day. A clean 5-gallon bucket was filled to the 4-gallon marker 3 times with the ozone water. In a clean 1000ml glass beaker, ozone was collected to the 800ml marker. Three dirty coupons were placed on the abrasion machine at a time per abrasion trial. Using a spray nossil, the ozone water was sprayed once on each dirty coupon and then once on a wypal towel. The machine was run for 20 cycles (30 seconds of cleaning), and then the clean coupons were removed to air dry overnight on a tray. This process was repeated for the 30min, 60min, 120min, and 240min mark for Series 1 with the same sample of ozone water per trial. Clean weights were recorded for percentage removal the next day.

DCC-17-33% vegetable shortening; 33% lard; 33% vegetable oil; 1% carbon lampblack.

Trial Results:

Cleaning levels were maintained over a 4-hour window.
Trial 1

Cleaner Coupon # Initial wt of cont. Final wt of cont. %Cont Removed
03 (0 Min) 16 0.5015 0.0381 92.40
03 (0 Min) 15 0.4997 0.0322 93.56
03 (0 Min) 27 0.4497 0.0335 92.55
03 (30 Min) 6 0.5055 0.0443 91.24
03 (30 Min) 31 0.5032 0.0353 92.98
03 (30 Min) 4 0.5001 0.0259 94.82
03 (60 Min) 25 0.4984 0.0275 94.48
03 (60 Min) 24 0.4999 0.0266 94.68
03 (60 Min) 14 0.5024 0.0267 94.69
03 (120 Min) 7 -0.3990 0.0278 106.97
03 (120 Min) 2 0.5405 0.0333 93.84
03 (120 Min) 4 1.1476 0.0266 97.68
03 (240 Min) 14 1.3192 0.0348 97.36
03 (240 Min) 26 1.1809 0.0452 96.17
03 (240 Min) 6 0.3776 0.0340 91.00

Trial 2

Trial 2        
Cleaner Coupon # Initial wt of cont. Final wt of cont. %Cont Removed
03 (0 Min) 20 0.5044 0.0405 91.97
03 (0 Min) 24 0.4265 0.0250 94.14
03 (0 Min) 3 0.5213 0.0342 93.44
03 (30 Min) 18 0.4989 0.0320 93.59
03 (30 Min) 4 0.5091 0.0325 93.62
03 (30 Min) 15 0.5052 0.0343 93.21
03 (60 Min) 26 0.5057 0.0237 95.31
03 (60 Min) 24 0.4926 0.0249 94.95
03 (60 Min) 6 0.5038 0.0452 91.03
03 (120 Min) 28 0.3610 0.0321 91.11
03 (120 Min) 15 0.4761 0.0332 93.03
03 (120 Min) 3 0.8423 0.0251 97.02
03 (240 Min) 5 0.6752 0.0253 96.25
03 (240 Min) 8 0.8218 0.0211 97.43
03 (240 Min) 13 0.5740 0.0224 96.10

Trial 3

Cleaner Coupon # Initial wt of cont. Final wt of cont. %Cont Removed
03 (0 Min) 13 0.5129 0.0441 91.40
03 (0 Min) 10 0.5837 0.0374 93.59
03 (0 Min) 6 0.5309 0.0416 92.16
03 (30 Min) 4 0.4779 0.0369 92.28
03 (30 Min) 16 0.3281 0.0420 87.20
03 (30 Min) 9 0.5738 0.0321 94.41
03 (60 Min) 28 0.4151 0.0428 89.69
03 (60 Min) 8 0.4793 0.0433 90.97
03 (60 Min) 25 0.5699 0.0438 92.31
03 (120 Min) 28 0.5843 0.0515 91.19
03 (120 Min) 17 0.5306 0.0434 91.82
03 (120 Min) 23 0.5183 0.0392 92.44
03 (240 Min) 14 0.5005 0.0507 89.87
03 (240 Min) 25 0.5517 0.0511 90.74
03 (240 Min) 21 0.5463 0.0440 91.95

Success Rating:

Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.

Conclusion:

Cleaning levels remained fairly constant over a four-hour time frame.