Trial Purpose:

To evaluate supplied product for grease removal (using DCC-17) from stainless steel and aluminum surfaces with an initial soak in cleaning solution prior to following TURI’s manual cleaning method.

Date Run:

05/10/2017

Experiment Procedure:

The following experimental procedure is in accordance with TURI’s cleaning a modified operating procedure for kitchen soil removal. The process added a soak prior to cleaning with manual washability unit.

Soiling Process:
A set of pre-weighed stainless steel and aluminum coupons were contaminated with 0.5 grams of DCC-17 soil using a handheld swab. Soil was applied onto the center of the coupon’s surfaces. The soil, DCC-17, was made with the following ingredients: Vegetable Shortening 33%, Lard 33%, Vegetable Oil 33%, and Carbon lampblack 1%. After all the stainless steel and aluminum coupons were contaminated with DCC-17 soil, the coupons sat overnight and then re-weighed to determine the amount of contaminant added.

Cleaning Process:
Three soiled substrates were immersed into a bath for the respective cleaning agent for five minutes at a temperature of 110 oF. The coupons were then cleaned in the Gardner Straight Line Washability unit for 20 cycles (~33 seconds). The cleaning solutions were diluted to the desired concentrations specified by the vendor. Two Wypall X60 reinforced wipe were attached to the cleaning sled prior to running the SLW machine.

Efficacy Rating Process:
The substrates were left to dry at room temperature for an hour before weighing to determine the amount of contaminant removed.

Trial Results:

For the high-end products, Vi-Jon Premium Pot & Pan had an efficacy rating at roughly 90% for stainless steel and 94% on aluminum. The Brady premium product was slightly higher on aluminum surfaces, 96% and nearly identical on stainless steel, 94%. The table below contains to the amount of contaminant added, the amount remaining and the percent removal by the respective cleaning agent to measure the efficacy of the cleaners.

Cleaner Initial wt(g) Final wt.(g) % Removed
Brady Premium Pot And Pan Stainless Steel      
  0.4815 0.0266 94.48
  0.4899 0.0346 92.94
  0.4896 0.029 94.08
Brady Premium Pot And Pan Aluminum      
  0.4885 0.0147 96.99
  0.488 0.0179 96.33
  0.4897 0.0183 96.26
Vi-Jon Premium Pot and Pan Stainless Steel      
  0.4896 0.0515 89.48
  0.4887 0.0493 89.91
  0.4914 0.0481 90.21
Vi-Jon Premium Pot and Pan Aluminum      
  0.4951 0.0243 95.09
  0.4936 0.0292 94.08
  0.4913 0.0307 93.75

Success Rating:

A cleanliness study, addressing only various analytical techniques.

Conclusion:

In conclusion, most effective to the least effective cleaning agents in removing DCC-17 soil after an initial soak in the cleaning solution are listed in the following order: Brady Premium Pot & Pan; Vi-Jon Premium Pot & Pan.