Trial Purpose:

To re-evaluate two supplied products for glass soap scum removal from two substrates using new dilutions.

Date Run:

08/17/2005

Experiment Procedure:

Two supplied cleaning product were diluted to vendor recommended concentrations for bathroom cleaning. The product was diluted with DI water.

Six preweighed fiberglass, six ceramic and six chrome coupons were coated with SSL Soil 1 (Bathroom soap scum: Vaseline Dry Skin Lotion 21.4%, Dial Clean Rinsing Body Wash 14.3%, Market Basket Shampoo & Conditioner (Pert) 28.6%, Soft Soap Natural Liquid hand soap 21.4%, Coast Deodorant bar soap 7.2% and Water 7.1%) using a hand held swab and allowed to dry for 24 hours at room temperature. The contaminated coupons were weighed again to determine the amount of soil added.

Three coupons were placed into a Gardner Straight Line Washability unit. A Professional Painter's Rag was attached to the cleaning sled and soaked with 5-7 sprays of cleaning solutions. Each coupon was sprayed 7-10 times with the same cleaning solution. The cleaning unit was run for 20 cycles (~33 seconds). At the end of the cleaning, coupons were wiped once with a dry paper towel. Final weights were recorded, efficiencies were calculated and recorded.

Trial Results:

The DFC 23 removed over 90% of the contaminant while used at the higher concentration. The DFC 5 removed % of the contaminant while used at the lower concentration. The table below lists the amount of soil applied and removed from the coupons.

Substrate Cleaner Initial wt Final wt % Removed
Ceramic DFC 23 0.1944 0.0245 87.40
    0.2456 0.0589 76.02
    0.2578 0.0273 89.41
  DFC 5 0.2095 0.0089 95.75
    0.0510 0.0018 96.47
    0.1671 0.0250 85.04
Fiber Glass DFC 23 0.2021 0.0156 92.28
    0.2705 0.0172 93.64
    0.4175 0.0003 99.93
  DFC 5 0.2841 0.0083 97.08
    0.3371 0.0065 98.07
    0.1876 0.0134 92.86
Chrome DFC 23 0.2103 0.0083 96.05
    0.1369 0.0085 93.79
    0.1366 0.0091 93.34
  DFC 5 0.2303 0.0171 92.57
    0.2562 0.0159 93.79
    0.2078 0.0147 92.93

Success Rating:

A follow up test, usually based on company input.

Conclusion:

Both products performed better at altered dilution ratios.