Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 2

Trial Purpose:

To evaluate successful cleaners from previous trials on second contaminant

Date Run:

09/15/2003

Experiment Procedure:

The eight products from the first trial were used again in this trial. Six products were used at full strength and two were products (Oakite Products and Gemtek Products) were used at 10%, diluted with DI water. Six products were used at room temperature and two products (Metabolix and Gemtek) were used at 120 F based on success from previous trial. Clean took place in 250 ml beakers with no agitation. The process utilized no water rinse and only used compressed air to dry/rinse the parts. Twenty-four preweighed steel coupons were coated with Rochester Midland Corp RI 780 (8052-41-3, 95-63-6) using a hand held swab. The coating then heated with a Master Appliance Heat gun at 300 F for 10 minutes. After cooling to room temperature, a second weighing was performed to determine the amount of soil that was added. Three coupons were cleaned in each solution for 5 minutes with no agitation. After drying with the air blow off, coupons were weighed a final time to determine the cleaning efficiencies of each product.

Trial Results:

All eight products removed over 88% of the coating from the steel coupons.  Five removed over 92% of the coating.  Solvent Kleene D Greeze 1000 was the most successful, removing 100% of the rust preventative in the five minutes of cleaning. The table below lists the amount of soil added and remaining for each coupon cleaned.

Cleaner Initial wt Final wt % Removed
AK 225 0.0544 -0.0001 100.18
  0.0152 0.0014 90.79
  0.0180 0.0007 96.11
DS 108 0.0250 0.0005 98.00
  0.0115 0.0011 90.43
  0.0242 0.0023 90.50
Beyond 2008 0.0334 0.0037 88.92
  0.0085 0.0006 92.94
  0.0097 0.0017 82.47
D Greeze 1000 0.0070 -0.0001 101.43
  0.0108 0.0002 98.15
  0.0156 -0.0002 101.28
278 Super Solv 0.0130 0.0009 93.08
  0.0282 0.0012 95.74
  0.0165 0.0018 89.09
Inproclean 3800 0.0161 0.0016 90.06
  0.0313 0.0023 92.65
  0.0379 0.0057 84.96
E3HB 0.0305 0.0003 99.02
  0.0129 0.0004 96.90
  0.0215 0.0025 88.37
SC Aircraft & Metal Cleaner 0.0155 0.0002 98.71
  0.0093 0.0005 94.62
  0.0089 0.0003 96.63

Success Rating:

Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.

Conclusion:

Increasing cleaning time may improve the efficiencies of the cleaners.  A follow up trial will be conducted for the products with less than 95% efficiency.

Save Report as a PDF