Trial Number 4

Trial Purpose:

To determine temperature dependance

Date Run:

03/08/1996

Experiment Procedure:

The purpose of this trial is to determine the temperature dependance of the two terpene chemistries as compared to NMP.
Three coupons will be cleaned in 500 ml of each solution at each temperature level (75F, 120F, 160F). Cleaning time will be for thirty minutes, and an acetone rinse will follow. All coupons were prepared and contaminated in the same method as previous experiments.
Data for cleaning efficiency at 160F will be imported from Phase II results to avoid redundant testing.

SUBSTRATE MATERIAL: 304 Stainless Steel Coupons
CONTAMINANTS: Durane Base Coatings #51144
CONTAMINATING PROCESS USED: Rubbed on with swab and allowed to cure overnight

Trial Results:

NMP- Room Temp

sample # clean mass (g) mass with contamination (g) mass after cleaning (g) contaminant removed (g) Percent Removal
19 60.2196 61.7264 60.8123 0.9141 60.67%
20 60.4776 62.0680 61.0376 1.0304 64.79%
27 60.2424 61.4824 60.5981 0.8843 71.31%
        2.8288 65.59%
          5.37%

Inland Tech EP-921- Room Temp

sample # clean mass (g) mass with contamination (g) mass after cleaning (g) contaminant removed (g) Percent Removal
11 60.7079 62.2201 61.5401 0.6800  44.97%
12 60.2775 61.6108 60.8862 0.7246 54.35%
14 60.5386 62.3071 61.7279 0.5792 32.75%
        1.9838 44.02%
          10.83%

 

Terpene Tech HTF85B-Room Temp

sample # clean mass (g) mass with contamination (g) mass after cleaning (g) contaminant removed (g) Percent Removal
6 60.4836 62.0351 61.0971 0.9380 60.46%
7 59.9048 61.4770 60.4385 1.0385 66.05%
10 60.0137 61.6361 60.7846 0.8515 52.48%
        2.828 59.67%
          6.82%

NMP-120F

sample # clean mass (g) mass with contamination (g) mass after cleaning (g) contaminant removed (g) Percent Removal
21 60.2213 61.9631 60.8190 1.1441 65.68%
22 60.0081 61.6345 60.2803 1.3542 83.26%
23 60.1057 61.5124 60.1346 1.3778 97.95%
        3.8761 82.30%
          16.15%

Terpene Tech. HTF85B: 120F

sample # clean mass (g) mass with contamination (g) mass after cleaning (g) contaminant removed (g) Percent Removal
16 60.5752 62.4356 60.6127 1.8229 97.98%
25 60.5201 62.1252 60.6090 1.5162 94.46%
28 59.9508 61.3642 59.9562 1.408 99.62%
        4.7471 97.35%
          2.64%

Inland Tech EP-921-120 F

sample # clean mass (g) mass with contamination (g) mass after cleaning (g) contaminant removed (g) Percent Removal
8 60.1098 61.4076 60.3152 1.0924 84.17%
24 60.2288 61.8040 60.6116 1.1924 75.70%
26 59.3009 60.6873 59.5260 1.1613 83.76%
        3.4461 81.21%
          4.78%

Success Rating:

A follow up test, usually based on company input.

Save Report as a PDF