Trial Purpose:

To evaluate supplied cleaner on four contaminants using ultrasonic energy

Date Run:

10/24/2002

Experiment Procedure:

The supplied product was used at full strength at room temperature. The product was poured into four 600 ml beakers and degassed for 5 minutes using a Crest 40 kHz ultrasonic tank. The four contaminants were applied onto sets of three coupons using a hand held swab. Contaminants were allowed to dry and then weighed again using the Denver Instruments A250 balance. One set of contaminated coupons were cleaned in the beakers for 2 minutes using ultrasonic energy. Coupons were dried using tap water at room temperature for 15 seconds and dried using a Master Appliance Heat Gun (except wax) at 500 F for 30 seconds. Once coupons were dry, final weights were recorded and efficiencies were calculated.

Contaminants: Grease - Daubert Chemical Co Tectyl 891 Class I cosmoline grease (8052-41-3, 68918-69-4, 64742-65-0, 68608-26-4)
Flux - Alpha 615 RMA flux (67-63-0, 8052-41-3, 8050-09-7)
Paint - Glidden Paint Company Ultra Hide Alkyd semi gloss paint (136-52-7, 1317-65-3, 1332-58-7, 66402-68-4, 8052-41-3, 64742-88-7, 71-43-2, 13463-67-7, 68604-95-5, 66070-62-0, 67746-05-8)
Wax - Stevenson Brothers and Co. Inc. Petroleum Paraffin wax.

Trial Results:

Again, the flux was easily removed from the steel coupons within the 2 minutes of cleaning. The paint removal was increased from 21% to over 84%. The cosmoline cleaning was slightly improve using ultrasonics whereas the wax showed no signs of improvement. Table 1 lists the efficiencies for the coupons cleaned in ultrasonics.

Table 1. Ultrasonic Efficiencies

Ultrasonics Cosmoline 55.23 35.15 17.66 36.01
  Flux 100.63 101.06 99.76 100.48
  Paint 85.10 90.31 76.72 84.05
  Wax 2.07 -10.54 0.34 -2.71

Success Rating:

A follow up test, usually based on company input.

Conclusion:

The supplied cleaner was successful on two of the four contaminants with the addition of ultrasonics.  Cosmoline removal may be increased by the addition of temperature or longer cleaning times.  From the data, wax removal does not appear to be a practical use for the supplied product.

Save Report as a PDF