Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 15

Trial Purpose:

To evaluate the effectiveness of SB-24 (92% Ektapro EEP, 8% t-butyl acetate), SB-32 (81% Ethyl Lactate, 19% Propylene Carbonate) and SB-41 (79% Ektapro EEP, 14%,ethyl lactate, 7% t-butyl acetate) in removing two production oils from stainless steel coupons as a potential replacement for TCE with an unheated ultrasonics cleaning method.

Date Run:

10/13/2023

Experiment Procedure:

Three stainless steel coupons were used for each cleaner and the two soils being tested, for a total of 18 coupons. The initial weights of each coupon were recorded. The bottom third of every coupon was soiled by applying the corresponding soil with a swab. The dirty weights of each coupon were then recorded. The coupons were then subjected to unheated ultrasonics in SB-24, SB-32, and the mixture for 15 minutes. After the coupons were cleaned, they were left to air dry over night. The next morning, the clean weights of each coupon were taken.

Trial Results:

Soil Cleaner Initial Content Weight Final Content Weight Percent Content Removed Average Percent Removed
CD Aero A SB-24 0.0674 0.0053 92.14 90.22
0.0388 0.0041 89.43
0.0403 0.0044 89.08
SB-32 0.0813 0.0037 95.45 85.65
0.0454 0.0155 65.86
0.0391 0.0017 95.65
SB-41 0.0483 0.0012 97.52 96.30
0.0324 0.0023 92.90
0.0657 0.0010 98.48
CD Aero C SB-24 0.0202 0.0023 88.61 91.36
0.0303 0.0026 91.42
0.0202 0.0012 94.06
SB-32 0.0210 -0.0014 106.67 106.74
0.0208 -0.0024 111.54
0.0444 -0.0009 102.03
SB-41 0.0506 0.0003 99.41 99.97
0.0329 -0.0006 101.82
0.0076 0.0001 98.69

Success Rating:

Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.

Conclusion:

The cleaners seemed to be effective at removing the soil but when left to air dry, the coupons that were cleaned in SB-32 and the mixture did not dry completely.

Save Report as a PDF