Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 0

Trial Purpose:

Control testing to monitor hucker's soil consistency.

Date Run:

12/14/2021

Experiment Procedure:

Nine pre-weighed coupons were contaminated with 0.5 grams of Hucker’s soil (Evaporated Milk; 26.5%, Creamy Peanut Butter; 17%, Salted Butter; 17%, Stone Ground Wheat Flour; 17%, Linseed Oil; 2.25%, Saline Solution; 5.25%, India Ink; 6.8%, Lemon Juice; 8.2%). Coupons were aged for two hours at room temperature (68°F) before dirty weights were recorded. Coupons of the same substrate were placed into the Straight Line Washability (SLW) unit, three at a time, and treated twice with water. A Wypall was attached to the SLW sled and was also treated twice with water. Each test ran 20 cycles (~30 seconds of cleaning). Coupons were air-dried at room temperature (68°F) overnight before final weights were recorded.

Trial Results:

Cleaner Substrate Initial wt of cont. Final wt of cont. %Cont Removed % AVG % Overall
Water Ceramic 0.5015 0.0961 80.84 79.59 79.92
0.4909 0.1136 76.86
0.4557 0.0862 81.08
Painted Steel 0.5672 0.1379 75.69 78.87
0.4965 0.0902 81.83
0.5168 0.1081 79.08
Plastic 0.5022 0.1124 77.62 81.3
0.4202 0.0679 83.84
0.5171 0.0908 82.44

Success Rating:

Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.

Conclusion:

The overall removal percentage for this control test was 79.92%.

Save Report as a PDF