Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 3

Trial Purpose:

To determine the efficacy of aqueous cleaners utilizing VCN methods.

Date Run:

04/20/2023

Experiment Procedure:

Eighteen pre weighed stainless steel coupons were used, three per soil per cleaner.  Half of the coupons were soiled by swabbing the bottom third of the coupons with J1 grease, while the other half of the coupons were soiled with J2 grease.  The dirty weights of all coupons were then recorded and visual rankings according to the key shown below were recorded.  The coupons were then subjected to a one-minute heated cycle at 140 degrees F in the VCN using Zymit 1% concentration and Micro 90 1% concentration.  The coupons were then removed and left to air dry overnight.  The next day the clean weights of the coupons were recorded and visual rankings were recorded.  

Visual Rankings Key

1= 100% of soil removed

2= 75% of soil removed

3= 50% of soil removed

4= 25% of soil removed

5= 0% of soil removed

Trial Results:

Cleaner soil Initial wt of cont. Final wt of cont. %Cont Removed % AVG % Overall
Zymit 1% J1 0.3911 0.0618 84.20 81.70 73.38
0.2952 0.0712 75.88
0.2528 0.0379 85.01
J2 0.4859 0.2152 55.71 65.07
0.5946 0.1912 67.84
0.5054 0.1432 71.67
Micro 90 1% J1 0.2474 0.0377 84.76 90.29 69.24
0.2963 0.0113 96.19
0.2866 0.0289 89.92
J2 0.4967 0.3226 35.05 48.20
0.4002 0.1925 51.90
0.5945 0.2518 57.65
Cleaner soil Dirty Visual Clean Visual AVG Clean Visual AVG Overall
Zymit 1% J1 5 4 4.2 4.33
5 4.5
5 4
J2 5 4 4.5
5 4.75
5 4.5
Micro 90 1% J1 5 2.25 2.2 3.33
5 2.75
5 1.5
J2 5 4.5 4.5
5 4.5
5 4.5

Success Rating:

Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.

Conclusion:

Both the Zymit 1% concentration and the Micro 90 1% concentration were only effective in removing J1 grease from stainless steel utilizing VCN methods.  Neither were effective in removing J2 grease.  

Save Report as a PDF