Trial Purpose:

To test nontoxic industrial cleaning solutions for oil removal

Date Run:

12/10/2008

Experiment Procedure:

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Products were selected based on the compatibility of substrate and removal of foreign substance. Used 5% concentration and heated the samples at 135F. The steel coupons were immersed in a product for 5 minutes, rinsed for 30 seconds in tap water at 120F and dried in 30 seconds using compressed air is room temperature. Coupons were coated with used oil. Using a handheld swab and allowed to dry for 144 minutes at room temperature. The contaminated coupons were weighed again to determine the amount of soil added. After cleaning process, the final weights were recorded, efficiencies were calculated and recorded.

Trial Results:

Cleaner Initial wt Final wt % Removed
Warren Chemical Company, Sea Wash 77      
  0.2494 0.0319 87.21
  0.1905 0.0310 83.73
  0.2560 0.0566 77.89
A1 Hydro Parke Hill, SW Wash 10      
  0.2619 0.0186 92.90
  0.3544 0.0298 91.59
  0.1791 0.0360 79.90
Kyzen Corporation, Me talnox-CP30      
  0.2577 0.0544 78.89
  0.1235 0.0270 78.14
  0.0695 0.0302 56.55
Kyzen Corporation, lonox 13302      
  0.2069 0.0436 78.93
  0.1452 0.0598 58.82
  0.1411 0.0527 62.65
Brulin Corporation, nonsilicated HTP      
  0.1714 0.0222 87.05
  0.1887 0.0316 83.25
  0.3632 0.0527 85.49
Brulin Corporation, Safety Strip S P96      
  0.1442 0.0485 66.37
  0.2834 0.0653 76.96
  0.2878 0.0556 80.68

Success Rating:

Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.

Conclusion:

Two products removed more than 85% of the Elcutt 51 oil from stainless steel using immersion cleaning.