Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 264

Trial Purpose:

Laboratory evaluations of alternative cleaning products

Date Run:

09/09/2003

Experiment Procedure:

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Five products were used at full strength, heated to 120 F on a hot plate. Fifteen preweighed coupons were coated with Quaker Chemical Ferrocoate 5815-LVO protective coating and allowed to dry overnight and reweighed. Three coupons were cleaned in each solution for 5 minutes using stir-bar-agitation, rinsed in a tap water bath for 15 seconds at 120 F and dried using air blow off for 30 seconds at 68 F. Coupons were allowed to dry overnight and then reweighed a final time. Efficiencies were calculated.

Note: Bio T Foam Plus was sprayed onto coupons at room temperature and allowed to sit for 5 minutes. The cleaner was then wiped clean.

Trial Results:

Only one product was partially successful in removing the coating.  Additional contact time may improve efficiencies for others as there was signs that the coating was starting to crack.

Success Rating:

Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.

Conclusion:

No products removed over 85% of the coating.

Save Report as a PDF