Trial Number 263

Trial Purpose:

Laboratory evaluations of alternative cleaning products

Date Run:

09/09/2003

Experiment Procedure:

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Five products were used at full strength, heated to 120 F on a hot plate. Fifteen preweighed coupons were coated with Quaker Chemical Ferrocoate 5815-LVO protective coating and allowed to dry overnight and reweighed. Three coupons were cleaned in each solution for 5 minutes using stir-bar-agitation, rinsed in a tap water bath for 15 seconds at 120 F and dried using air blow off for 30 seconds at 68 F. Coupons were allowed to dry overnight and then reweighed a final time. Efficiencies were calculated.

Note: Bio T Foam Plus was sprayed onto coupons at room temperature and allowed to sit for 5 minutes. The cleaner was then wiped clean.

Trial Results:

Only one product removed over 85% of the coating. The other four may be effective with longer cleaning times or the use of additional mechanical energy.

Success Rating:

Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.

Conclusion:

AW Chesterton was successful in removing the coating.