Browse Client Types

Browse past lab clients by general industry sectors

Trial Number 227

Trial Purpose:

Laboratory evaluations of alternative cleaning products

Date Run:

02/05/2003

Experiment Procedure:

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Cleaning: 5 min Immersion cleaning with stir-bar agitation @ 120 F
Rinsing: 1/2 min, manual, in 120 F water (tap)
Drying: 1 min with heat gun @ 500F
Contaminant: Magnum Teflon Lubricant (LPS)
CAS# 64742-96-7, 64742-65-0, 68602-85-7, 58755-77-3, 124-38-9

Success Rating:

Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.

Save Report as a PDF