Trial Purpose:

Laboratory evaluations of alternative cleaning products

Date Run:

03/25/2002

Experiment Procedure:

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Heating in oven at 100 C and observing the change in weight at 10 min., 30 min., 60 min.

1. Coating - The Valvoline Co. Tectyl 506 Petroleum based rust preventative
2. Resin - Solutia Inc. Gelva Multipolymer Resin Solution 2895 (50862-46-9, 141-78-6, 142-82-5, 67-63-0, 64-17-5, 108-05-4)

3. Cutting Fluid - Bencyn, Inc. B-5186, Metal Working Compound (64742-52-5, 9003-29-6, 39464-69-2, 63197-48-8)

Trial Results:

Not much removal was observed.

Success Rating:

Preliminary compatibility tests on substrate coupons encouraging for at least one cleaning chemistry. More in-depth laboratory testing necessary.