Trial Number 5

Trial Purpose:

To compare parts cleaned in three different solutions using OSEE.

Date Run:

08/31/1999

Experiment Procedure:

Parts were received cleaned by client. Five OSEE readings were made per side for each part supplied. Optically Stimulated Electron Emission or PEE, Photo Electron Emission is based on the principle that metals and certain surfaces emit electrons upon illumination with ultraviolet (UV) light. These electrons can be collected, measured as current, converted to a voltage and digitally displayed. A surface contaminant will either enhance or attenuate this signal, depending on it own photoemissive nature. While OSEE will not identify a contaminant, it is a good comparative tool to determine the degree of contamination. This method is best suited for thin films (oils, etc.) and not particulate matter (dust, for example). The average values were calculated and compared to current cleaner levels.
The solutions used were:
Current Cleaner Mix Almet B & Chem-Crest
Oakite Products Inpro-Clean 3800
Calgon Corp SMS 206

SUBSTRATE MATERIAL: Aluminum Parts (5052)
CONTAMINANTS: Clean Parts for Analysis
CONTAMINATING PROCESS USED: N/A

Trial Results:

Of the two new products being compared, Calgon Corp had readings that were most similar to the current cleaning solution. Table 1 lists the readings made from both top (shiny) and bottom sides of supplied parts.
Table 1. OSEE Readings

Cleaner Current  Cleaner Oakite Calgon    
Location  Top Bottom Top Bottom Top Bottom
  396 728 269 778 297 932
  482 783 259 742 342 926
  413 674 242 704 364 930
  514 760 251 802 302 931
  528 670 234 704 291 932
  798 721 458 625 821 925
  838 725 439 601 841 925
  840 808 478 561 812 927
  696 641 524 542 880 932
  736 718 401 523 758 931
  799 784 269 567 829 932
  822 907 375 571 823 926
  742 666 287 569 736 929
  702 721 442 573 890 931
  700 765 290 628 747 931
  659 701 363 590 792 930
  772 687 415 601 780 921
  853 754 409 611 798 933
  611 714 332 646 769 930
  688 577 280 558 738 931
  754 739 407 584 778 912
  657 814 429 697 931 918
  585 640 444 642 869 923
  642 636 447 573 847 929
  570 522 419 598 697 926
  781 686 343 613 868 926
  815 836 338 550 870 924
  895 736 274 646 839 927
  773 655 363 639 913 920
  612 606 304 558 779 927
  891 754 335 719 824 919
  819 803 405 595 861 931
  708 863 440 541 834 926
  667 786 304 673 831 929
  710 621 369 651 809 932
  811 498 248 272 849 387
  808 527 392 252 893 339
  744 479 371 245 840 364
  656 390 259 254 930 459
  688 323 225 246 751 288
Average  704 685 353 576 761 857

Success Rating:

A cleanliness study, addressing only various analytical techniques.

Conclusion:

From the OSEE readings made, the Calgon product yielded values that were similar to the current levels.  The average Top readings were 761 for Calgon and 704 for the Current cleaner.  The Bottom values averaged 857 for Calgon and 685 for the Current cleaner.