Client Number 18 (Electronics Manufacturer)


Client Images:

Client Image http://www.cleanersolutions.org/downloads/client_images/018A.jpg   


Project Number 1



Summary: The lab suggested separating the two contaminants and cleaning the coating in the vapor degreaser and the flux in an aqueous bath. The lab had tested Ecolink 2005 and NMP. Client opted to switch over to a two solvent system using Axarel and IPA.

Test Objective: Replacement of Vapor Degreaser for cleaning of PCB's, ceramic substrates with RMA flux

Problems with Current Method: Hazardous waste generated by the degreaser. Safety concerns, explosive limits

Purpose of Cleaning: removal of flux & solder paste residues

Product Use: Radar systems

Cleaning Chemicals: Methylene Chloride

Trial Number Date Run Purpose Success Rating
0 01/02/96 Identify cleaners to remove flux and Hummiseal Test inconclusive. 
1 02/12/96 Removal of conformal coatings Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined. 
2 01/18/96 To evalaute possible alternatives form hummiseal and flux removal Results successful using TACT (time, agitation, concentration, and temperature, as well as rinsing and drying) and/or other cleaning chemistries examined.